W and UW valves: operation and cleaning
Precautions and instructions for disassembling, cleaning, and reassembling W and UW type Valco valves.
TEST - Copy of Tech Note Library
TEST - Technical Note Library
Browse technical notes by number and product category. Each note includes a PDF, a brief description, and a video where available.
Looking for other documents? Visit Dimensional Drawings or Technical Resources.
Search by note number, product, model, or keyword.
100s — Valco valves, general information (0 notes)
200s — Valco valves, two position (10 notes)
4-port internal sample injector
Schematic flow diagram for the 4-port internal fixed-volume sample injector, W and UW valves, all series.
6-port external volume sample injector
Schematic flow diagram for the 6-port external volume sample injector, W and UW valves, all series.
8-port external volume sample injector
Schematic flow diagram for the 8-port external volume sample injector, W and UW valves, all series.
10-port multifunctional valve
Schematic flow diagram for the 10-port multifunctional W and UW type valve, all series.
4-port switching valve
Schematic flow diagram for the 4-port switching valve, W and UW valves, all series.
3-port switching valve
Schematic flow diagram for the 3-port switching valve, W and UW valves, all series.
Dual sample size internal volume injectors
Instructions for rotating the rotor to change between the two sample sizes of a dual-volume injector.
Simultaneous injection: same sample onto 3 columns
A 14-port valve plumbing arrangement for loading the same sample into three loops and injecting onto three columns.
Simultaneous injection: 2 samples, 2 columns
A 12-port valve arrangement for loading and injecting two different samples onto two different columns.
300s — Older Valco valves, with external coil spring (2 notes)
P and E series valves: operation and cleaning
Operation notes, precautions, disassembly, cleaning, and reassembly for P and E series Valco valves.
10-port multifunctional P type valve
Schematic flow diagram for a two-position 10-port multifunctional switching valve, P type, all series.
400s — Valve actuation (3 notes)
Two-position helical drive air actuator
Implementation of Valco two-position air actuators using older solenoids; includes the paired 3-way solenoid arrangement.
Multiposition helical drive air actuator
Implementation using a 4-way solenoid and continuous air application for Valco multiposition actuators.
Position feedback for two-position air actuators
Installing Position Feedback for Air Actuators (PFAF) to provide permanent contact closure feedback.
500s — Fittings (9 notes)
Fused silica adapters
Installation and use of fused silica adapters for open tubular columns and Valco fittings.
Cheminert connecting accessories
Using the flanging tool to prepare PTFE tubing and assemble Cheminert tube end fittings.
Valco fitting instructions
Tubing preparation and assembly instructions for metal and PEEK zero dead volume fittings.
EZR and IZR installation instructions
Installing external and internal reducers to adapt existing fittings and small transfer lines to Valco connections.
Cheminert flangeless fittings with collapsible ferrule
Assembly instructions for the one-piece collapsible ferrule used in Cheminert flangeless fittings.
IZERA1.5 installation instructions
Installation of 1/16-inch internal to 1/32-inch external adapters designed to prevent graphite ferrules sticking.
Cheminert one-piece 1/32-inch nanovolume fittings
Initial assembly and reuse of one-piece fittings with a breakaway grooved ferrule.
Cheminert 360 µm fittings
Installation and use of high-pressure fittings for direct connections to 360 µm OD tubing.
Zero dead volume fill port fittings
Installation and needle-seal adjustment for the ZVISF-1 fill port fitting and its polymer bushing.
600s — Miscellaneous (8 notes)
Micrometering needle valves
Mounting and operating notes for BNV1 and ZBNV1 bulkhead-mounted micrometering valves.
DV-12 and DV-22 diaphragm valves: operation
Installation, actuation, and operating instructions for DV-12 and DV-22 sample injectors.
DV-12 and DV-22: diaphragm replacement
Disassembly and diaphragm replacement procedures for DV-12 and DV-22 valves.
Air-actuated Valco on/off valves
Installation and operation of high-pressure air-actuated Valco on/off valves.
Model 202 flow controller
Specifications and adjustment instructions for the upstream-referenced Model 202 flow controller.
Lapping ends of fused silica tubing
Using the Fused Silica Prep Kit to produce clean, square tube ends for low dead volume connections.
DV-13 and DV-23 diaphragm valves: operation
Installation, actuation, and operating instructions for DV-13 and DV-23 sample injectors.
DV-13 and DV-23: diaphragm replacement
Disassembly and diaphragm replacement procedures for DV-13 and DV-23 valves.
700s — Valco selectors (multiposition valves) (1 note)
MW and UW selectors: cleaning and alignment
Cleaning, rotor replacement, and alignment for MW and UW multiposition selectors on microelectric or universal actuators with keyed hardware.
800s — Cheminert valves (8 notes)
Cheminert HPLC and UHPLC injectors
Cleaning, inspection, and rotor replacement instructions for Cheminert HPLC and UHPLC injectors.
Cheminert C1 and C1CF: installation and maintenance
Panel mounting, fitting connections, use, and maintenance for Cheminert C1 and C1CF valves.
Cheminert 4-port internal sample injector
Schematic flow diagram for 4-port internal fixed-volume Cheminert injectors, high- and low-pressure models.
Cheminert C22(Z), C24(Z), and C25(Z)
Cleaning and rotor replacement for Cheminert C22, C24, C25, C22Z, C24Z, and C25Z models.
Cheminert CN2 and CN4: cleaning and rotor replacement
Maintenance and fitting precautions for CN2 and CN4 valves with 100-micron flowpaths and one-piece nanovolume fittings.
Cheminert flow-through stream selectors
Schematic flow diagrams for selectors that vent non-selected streams, including the Model C5F.
Cheminert C55 and C65(Z) selectors
Installation, electrical connections, motor control, and maintenance for C55, C65, and C65Z selectors.
Cheminert C42R: cleaning and rotor replacement
Cleaning, disassembly, and rotor replacement for the Cheminert Model C42R valve.
No matching notes. Try a different note number, model, or keyword, or clear your search.